User Tools

Site Tools


playground:wiki3:gateway_sw_3.2

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
playground:wiki3:gateway_sw_3.2 [2020/06/11 13:26]
tda
— (current)
Line 1: Line 1:
- 
-====== v3.2 Gateway Software Releases ====== 
-\\ 
-\\ 
-This version is designed to **upgrade a system with a KerOS 4.x installed** (3.1 embedded software). 
- 
-To update a system which KerOS version is lower than 4.x, the **liveburner 4.0** available ​ [[http://​wikikerlink.fr/​wanesy-ran/​doku.php?​id=wiki:​wiki3:​gateway_sw_3.1#​download|here]] need to be applied first before applying the current update. 
- 
-To update a system from KerOS 4.x, either install packages from USB stick or copy the megapackage in the folder ///​user/​.updates//​ on the gateway and deflate it or use the [[.magic_link|magic link]]. 
- 
-https://​wikikerlink.fr/​wanesy-ran/​doku.php?​id=playground:​wiki3:​gateway_sw_3.2&​do= 
-This release version is designed for: 
- 
-  * **Wirnet iBTS**, 
-  * **Wirnet iFemtoCell**,​ 
-  * **Wirnet iStation**. 
- 
-<note important>​**CAUTION with gateways that are statically IP assigned** \\ 
-You may loose the WMC connection! Follow the procedure described [[wiki:​wiki3:​faq_gw_upgrade_3.2#​how_to_upgrade_my_gateway_that_is_static-ip_assigned_with_32_embedded_software|here]]</​note>​ 
- 
- 
-For the **Wirnet Station**, the 3.1 SW release must be used to connect a Wirnet Station to the WMC server v3.2.  
- 
-For lucky owners of **Wirnet iFemtoCell-evolution**,​ please refer to [[wiki:​wiki3:​gateway_sw_3.3|this specific software]]. 
- 
- 
-<note important>​**CAUTION:​ \\ \\ 
-Theses packages are only dedicated to connect gateways to WMC v3.2. \\ They are not intended to be used with WMC 2.3, 3.0 or 3.1.** 
-</​note>​ 
- 
-===== Download ===== 
- 
-^ Product ​                ^ Megapackage ​       ^md5sum ​     ^                          
-| **Wirnet iBTS \\ Wirnet iFemtoCell \\ Wirnet iStation** | \\ {{ :​wiki3:​wmc_megapackage_for_keros_v3.2.5.tar.gz |}} | \\ 07344dade5adcf7dc6d2f36212b6425f | 
-| **Wirnet Station** | {{ :​wiki3:​fwupgrade_wirmav2_wirnet_v3.6_wmc_v3.1.6.tar.gz | fwupgrade_wirmav2_wirnet_v3.6_wmc_v3.1.6.tar.gz}} ​ | b74737609413bb65b5f68716568da150 | 
-\\ 
-\\ 
-For **all products except the Wirnet Station**: 
-^Component ^Version ^  
-| **keros** | 4.1.6    |  
-| **bscc** | 3.2.4    |  
-| **lorasnmp** ​ | 3.2.4    |  
-| **lorad** | 1.1.5-2 ​ |  
-| **lorafwd** | 1.1.1-2 ​ |  
- 
-For the **Wirnet Station**: 
-^Component ^Version ^  
-| **keros** | 3.6    |  
-| **bscc** | 3.1.6    |  
-| **lorasnmp** ​ | 3.1.6    |  
-| **lorad** | 1.0.5-2 ​ |  
-| **lorafwd** | 1.0.7-2 ​ |  
-\\ 
-There are 3 ways to update your gateway'​s software: 
-  * by using [[.magic_link|Magic link]] 
-  * by using an [[.gateway_sw_3.2#​software_update_over_usb|USB stick]] 
-  * by using [[.gateway_sw_3.2#​software_update_over_ethernet|Ethernet connection (SSH)]] 
-  * over WMC dashboard, by using the [[wiki:​wiki3:​install_upgrade#​wmc_drag_n_drop_feature|Drag and drop feature]] 
-\\ 
-\\ 
-===== Software update over ethernet ===== 
-\\ 
-This procedure can be used to **UPGRADE from a KerOS 4.x system** on a **single** gateway. \\ 
- 
-To update your gateway, apply the following procedure: 
-  - Request your VPN package(s) to the Kerlink Support team: [[support@kerlink.fr]] (optional: in case of a First Install or Migration) 
-  - Transfer package(s) in this directory: <code bash> 
-# From a computer: 
-scp WMC_embedded_keros_v3.3.5.tar.gz openvpn-*.ipk root@<​ip_address>:/​user/​.updates/​ 
-</​code>​ 
-  - Deflate archive and ensure file is correctly written: <code bash># On the gateway: 
-cd /​user/​.updates 
-tar -xzf *.tar.gz 
-rm -f WMC*.tar.gz 
-sync </​code>​ 
-  - Trigger Update for next reboot: <code bash>​kerosd -u </​code>​ 
-  - Restart: <code bash>​reboot</​code>​ 
- 
-\\ 
-Refer to [[http://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​keros_custo:​sw_updates#​software_update_over_network|software update procedure]] for further details. 
- 
-\\ 
-===== Software update over USB =====  
-\\ 
-==== For all products except the Wirnet Station ==== 
-\\ 
-This procedure used for automatic deployment can be used to **UPGRADE from a KerOS 4.x system** (embedded software 3.1.x) on a **single** or a **group of gateways**. \\ 
-If you want to install this sotfware from a KerOS 3.x, you need to install a KerOS 4.x before upgrading your system. ​ 
- 
- 
-**You need to use 1 or 2 USB sticks depending on your FW version **. \\ \\ 
- **If your KerOS version is lower than 4.0 then you will need to create 2 USB sticks.** \\ 
- 
- 
-^                   ​^ ​    FW 3.1        ^    FW 3.4     ​^ ​   FW 4.0  ^    
-| Nb of USB sticks ​   |     ​2 ​    ​| ​    ​2 ​       |    1        |    ​ 
- 
-When using 2 USB sticks: \\ 
-  
-  * The **first USB stick** will upgrade the firmware to **KerOS 4.1**. ​ 
-  * The **second USB stick** will **install all others packages** with the required software release: BSCC, SNMP, Common Packet Forwarder (CPF) and OpenVPN packages. 
- 
-When using a single USB Stick: \\ 
- 
-  * Put the file .tar.gz on your USB stick and decompress all the stuff in the root directory. 
- 
-To update your system from a KerOS 4.x system, use the following software: 
- 
-^description ​                ​^file ​       ^md5sum ​     ^ 
-|**USB stick ** | {{ wiki3:​auto_deploy_3.3.5_keros_usb_stick.tar.gz | AUTO_DEPLOY_3.3.5_KEROS_USB_STICK.tar.gz }} |  b1a144d2cf9ec866b4c6fd97f44a2c7c ​ | 
-The same USB stick can be used twice. 
- 
-**The .tar.gz file provided below is "​ready-to-use"​**. ​ 
-You only need to copy your OpenVPN packages on the USB stick: your OpenVPN secrets files in //​vpn_packages//​ directory and your OpenVPN config file in the //COMMON// directory to be able to connect properly to your WMC server. 
- 
-\\ 
-To update your gateway, apply the following procedure : 
- 
-> 1. Deflate twice the tar.gz file to get .ipk files and put them on your USB stick in the root directory 
-> 2. Copy all files located in the folder AUTO_DEPLOY_3.2.5_KEROS_USB_STICK in the root directory 
-> 3. Request your VPN package(s) to the Kerlink Support team: [[support@kerlink.fr]] (optional: in case of a First Install or Migration) 
-> 4. Put your VPN config packages in the //COMMON// directory to connect to YOUR WMC server (optional: in case of a First Install or Migration) 
-> 5. Put your VPN secrets packages of your KerOS products in the //​vpn_packages//​ directory (optional: in case of a First Install) 
-> 6. Plug the USB stick in the gateway USB slot (device must be powered on) 
-> 7. Wait the end of the update ​ 
-> 8. Plug the second USB stick in the gateway USB slot (if needed) 
-> 9. Wait the end of the update (if needed) 
- 
-Refer to the specific wiki to get more details about software update over USB: \\  
-**Wirnet Product Line (iBTS, iFemtocell, iStation)**:​ [[http://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​keros_custo:​sw_updates#​software_update_over_usb]] \\ 
-\\ 
-\\ 
-==== For the Wirnet Station ==== 
- 
-The update procedure uses 2 USB sticks: \\ 
-  
-  * The **first USB stick** will upgrade the firmware to **KerOS 3.6.** ​ 
-  * The **second USB stick** will install **all others packages** with the required software release: BSCC, SNMP, Common Packet Forwarder (CPF) and OpenVPN packages. 
- 
-^description ​                ​^file ​       ^md5sum ​     ^ 
-|**USB stick number 1** | {{:​wiki3:​auto_deploy_3.1.6_usb_stick_1.tar.gz | AUTO_DEPLOY_3.1.6_USB_STICK_1.tar.gz}} | 6c31bebc9f2942bb852adecd74a57284 | 
-|**USB stick number 2** | {{:​wiki3:​auto_deploy_3.1.6_usb_stick_2.tar.gz | AUTO_DEPLOY_3.1.6_USB_STICK_2.tar.gz}} | 0835b621155886559b19dc46604e4cc7 | 
- 
-> 1. Deflate twice the tar.gz file on each USB stick in the root directory 
-> 2. Copy files located in the folder AUTO_DEPLOY_3.1.6_USB_STICK_x in the root directory 
-> 3. Add your OpenVPN packages in AUTO_DEPLOY_3.1.6_USB_STICK_2 before plugging the stick into the system. 
-> 4. Plug the first USB stick in the gateway USB slot 
-> 5. Wait the end of the update 
-> 6. Plug the second USB stick in the gateway USB slot 
-> 7. Wait the end of the update 
- 
- 
- 
-Refer to the specific wikis to get more details (ex led management) about software update via USB sticks: \\ \\ 
-Wirnet Station: [[http://​wikikerlink.fr/​lora-station/​doku.php?​id=wiki:​updates#​usb_update_recommended]] 
-\\ 
-\\ 
- 
-==== USB stick content ==== 
- 
-The USB tree should contains the following files/​folders:​ 
- 
-<​code>​ 
-/                
-├── COMMON ​                                               # KerOS products packages folder (iBTS, iFemtoCell, iStation) 
-│   ​├── keros_***_klkgw.ipk ​                              # Keros firmware package for Wirnet iBTS 
-│   ​├── bscc_***_klkgw.ipk ​                               # WMC BSCC package for Wirnet iBTS 
-│   ​├── lorasnmp_***_klkgw.ipk ​                           # WMC SNMP package for Wirnet iBTS 
-│   ​├── lorad_***_klkgw.ipk ​                              # HAL package for Wirnet iBTSpk 
-│   ​├── lorafwd_***_klkgw.ipk ​                            # Packet Forwarder package for Wirnet iBTS 
-│   ​└── openvpn_config_wmcbeta.wanesy.com_3.1.ipk ​        # sample file: the WMC server to connect to 
-├── README.txt ​                                           # This file 
-├── usb.autorun ​                                          # executed by KerOs products when plugging the USB stick 
-├── usbkey.txt ​                                           # USB key protection: must contain the device passwords (all of them) 
-└── vpn_packages ​                                         # WMC OpenVPN packages folder 
-    ├── openvpn_secrets_***_wmcbeta.wanesy.com_***.ipk ​           # OpenVPN package for one KerOS product to connect to a WMC platform (here wmcbeta) 
-    ├── openvpn_secrets_***_wmcbeta.wanesy.com_***.ipk ​           # another package for one KerOS product to connect to a WMC platform (here wmcbeta) 
-    ├── openvpn_secrets***_wmcbeta.wanesy.com_***.ipk ​            # ... 
-    ├── openvpn_secrets_***_wmcbeta.wanesy.com_***.ipk ​           # ... 
-    ├── openvpn_secrets_***_wmcbeta.wanesy.com_***.ipk ​           # ... 
-    ├── openvpn_secrets_***_wmcbeta.wanesy.com_***.ipk ​           # ... 
-    └── openvpn_secrets_***_wmcbeta.wanesy.com_***.ipk ​           # ... 
- 
-</​code>​ 
-\\ 
-\\ 
-===== Changelog ===== 
- 
-Main changes regards to the 3.1 embedded software release are listed below: 
- 
-<​code>​ 
-- iStation gateway support 
-- New power management for iStation 
-- Backhaul configuration improvement 
-</​code>​ 
-\\ 
-===== Restrictions ===== 
-<​code>​ 
-- Spectral scan with LBT mode enabled does not work properly 
-</​code>​ 
- 
-\\ 
-\\ 
- 
-===== Warranty ===== 
- 
-<note important>​ 
-**CAUTION ABOUT WARRANTY:** \\ 
-**Kerlink is not responsible for damage arising from failure to follow these instructions relating to the Kerlink Product’s use.** 
-</​note>​ 
- 
- 
  
playground/wiki3/gateway_sw_3.2.1591874802.txt.gz · Last modified: 2020/06/11 13:26 by tda