This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
wiki:wiki3:faq_general_3.x [2019/11/14 16:24] bdu EUI for iStation and iFemto-evo |
wiki:wiki3:faq_general_3.x [2021/06/03 15:39] (current) tda |
||
---|---|---|---|
Line 3: | Line 3: | ||
===== How can I obtain the EUI from the serial number of my station? ===== | ===== How can I obtain the EUI from the serial number of my station? ===== | ||
- | ^ Product ^ EUI ^ Example | | ||
- | |Wirnet iBTS |7276FF002E<last 6 characters of the CPU serial number> |''7276FF002E060337''| | ||
- | |Wirnet Station |7276FF000<last 7 characters of the station barcode> |''7276FF00080E0761''| | ||
- | |Wirnet iFemtoCell |7276FF00<last 8 characters of the CPU board serial number> |''7276FF003903046C''| | ||
- | |Wirnet iStation |7076FF00<last 8 characters of the CPU board serial number> |''7276FF005403046C''| | ||
- | |Wirnet iFemtoCell-evo |7076FF00<last 8 characters of the CPU board serial number> |''7276FF006403046C''| | ||
- | For the iFemtoCell, you can retrieve the CPU serial number with the following command: | + | ^ Product ^ EUI ^ Example ^ |
+ | |Wirnet Station |7276FF00<board_type><last 6 characters of the station barcode> |''7276FF00080E0761''| | ||
+ | |Wirnet iBTS |7276FF002E<last 6 characters of the CPU module serial number> |''7276FF002E060337''| | ||
+ | |Wirnet iFemtoCell |7276FF00<last 8 characters of the CPU serial number> |''7276FF003903046C''| | ||
+ | |Wirnet iStation |7076FF00<last 8 characters of the CPU serial number> |''7076FF005403046C''| | ||
+ | |Wirnet iFemtoCell-evo |7076FF00<last 8 characters of the CPU serial number> |''7076FF006403046C''| | ||
+ | |||
+ | For Wirnet Station, the **board_type** can be defined like that: | ||
+ | |||
+ | ^ board_type ^value ^ | ||
+ | | SOP3 | 08 | | ||
+ | | SOP4 | 0B | | ||
+ | |||
+ | For i-Series products, the 2 first digits of the serial number indicates the region and this region can be defined like that: | ||
+ | |||
+ | ^ Product ^ region ^value | | ||
+ | |Wirnet iBTS | All regions | 2E | | ||
+ | |Wirnet iFemtoCell | EU-868 \\ US-915 \\ AS-923 | 39 \\ 44 \\ 45 | | ||
+ | |Wirnet iStation | EU-868 \\ US-915 \\ AS-923 | 56 \\ 55 \\ 54 | | ||
+ | |Wirnet iFemtoCell-evo | EU-868 \\ US-915 \\ AS-923 | 64 \\ 65 \\ 66 | | ||
+ | |||
+ | You can retrieve the CPU serial number with the following command: | ||
<code bash> | <code bash> | ||
root@klk-wifc-01AAFF:~ # grep serial_number /tmp/sys_startup_status.json | root@klk-wifc-01AAFF:~ # grep serial_number /tmp/sys_startup_status.json | ||
"serial_number": "0x4501aaff", | "serial_number": "0x4501aaff", | ||
</code> | </code> | ||
- | In this example, the EUI is ''7276FF004501AAFF''. | + | Construct the EUI by adding the ''7276FF00'' pattern and add the serial number to obtain''7276FF004501AAFF''. \\ |
+ | **Care, for Wirnet iStation and Wirnet iFemtoCellEvo, the prefix pattern has changed from ''7276FF00'' to ''7076FF00''.** | ||
- | ===== How do I move a gateway from a fleet to another fleet? ===== | + | To retrieve directly the EUI value, you can retrieve it with the following command: |
- | + | <code bash> | |
- | You can move a gateway from a fleet to another fleet from: | + | root@klk-wifc-01AAFF:~ # grep EUI /tmp/sys_startup_status.json |
- | - The cart: add one or more gateway to the cart, click on the cart icon and then use the move action to move your gateways | + | "EUI64": "7276FF004501AAFF", |
- | - The gateway overview page: go on the main page of the gateway you want to move and click on the floating button to edit the gateway. Select another fleet to move the gateway | + | </code> |
===== How can I put a gateway in two fleets? ===== | ===== How can I put a gateway in two fleets? ===== | ||
Line 37: | Line 53: | ||
===== What is the maximum number of gateways we can define? ===== | ===== What is the maximum number of gateways we can define? ===== | ||
- | * We can limit the number of gateways, the number of endpoints and number of users linked to a customer via the administration menu (only accessible for users that have SuperAdmin privileges) | + | We can limit the number of gateways, the number of endpoints and number of users linked to a customer via the administration menu (only accessible for users that have SuperAdmin privileges). |
===== What is the maximum number of gateways we can define in the CSV file? ===== | ===== What is the maximum number of gateways we can define in the CSV file? ===== | ||
- | * There is no limit | + | There is no limit. |
===== When we define a CSV, is it a "add" or a "replacement"? ===== | ===== When we define a CSV, is it a "add" or a "replacement"? ===== | ||
- | * Add | + | Add |
===== What happens when a mote is already defined in the system and when we try to add it again through the CSV file? ===== | ===== What happens when a mote is already defined in the system and when we try to add it again through the CSV file? ===== | ||
- | * An exception is raised and the process stops | + | An exception is raised and the process stops. |
===== What happens when the CSV file embodies a syntax error? ===== | ===== What happens when the CSV file embodies a syntax error? ===== | ||
- | * An exception is raised and the process stops when the error is encountered. All lines located before this point are taken into account by the system | + | An exception is raised and the process stops when the error is encountered. All lines located before this point are taken into account by the system. |
===== When a mote is removed, is data related to this end-device is also removed? ===== | ===== When a mote is removed, is data related to this end-device is also removed? ===== | ||
- | * Yes | + | Yes. |
===== When a gateway is removed, is data related to all end-devices that are connected to are also removed? ===== | ===== When a gateway is removed, is data related to all end-devices that are connected to are also removed? ===== | ||
- | * No | + | No. |
===== I have got a frame counter error (FCnt error). What can I do to cancel this status? ===== | ===== I have got a frame counter error (FCnt error). What can I do to cancel this status? ===== | ||
- | * In the LNS / endpoint menu, click on your endpoint and then click to the cross at the right side of the text "FRAME COUNTER DOWN" | + | In the LNS / endpoint menu, click on your endpoint and then click to the cross at the right side of the text "FRAME COUNTER DOWN". |
- | * Select F5 for page refresh several times | + | Select F5 for page refresh several times. |
- | => Status "Uplink ok" appears and uplink message queue is updated with new messages in "Rx messages" tab | + | => Status "Uplink ok" appears and uplink message queue is updated with new messages in "Rx messages" tab. |
===== What is the VPN subnet address? ===== | ===== What is the VPN subnet address? ===== |