Network Delays configuration

Network Delay configuration helps target the RX1 window when sending TX messages to an end device.

Configuration

On the LNS section of each gateway, the network delay uplink and downlink can be configured. By default it is 350ms. Here is how it looks like:

This value is an indication of the network delays that the gateway has towards and from the LNS server.

Behavior

When an end-device sends a LoRa packet, each gateway that receives it will forward it to the LNS server. The LNS server will wait 350ms after having received the first packet, in order to aggregate all the copies of that packet sent by each individual gateway.

It will then try to see which window is best to send the TX message to the end device. To do so, it will add the network delay down to the current time, and see if this fits, with an additional 50ms margin. If this allows to reach the RX1 window delay (usually one second), then it will send it soon. If this doesn't allow to reach the RX1 window, it will target the RX2 window (usually two seconds).

RX window decision

So the RX window decision is basically:

T0 = now - Ndu
Test = T0 + Tagg + Ndd + hr
Decision = Test-T0 < 1000 ?
Ttx = T0 + Twin - Ndd

with:

Example

Inputs:

Computation:

Behavior:

Notes

Actual behaviors

Several situations may arise:

Very good backhaul (<100ms RTT)

This is the nominal case. The LNS will always target the RX1. The configured delays on the dashboard are the default values (350ms).

Fair backhaul (300ms RTT)

This is an edge case of the nominal case. The LNS will miss the RX1 depending on the actual network delay. The configured delays on the dashboard are the default values (350ms).

In this example, the RX1 is missed. If the network delay had been configured to 300ms, the RX1 window may have been reachable.

In this case, it is very important to reconfigure the network delay on the dashboard. This will help reach the RX1 window as soon as the actual network delay is good.

Not good backhaul (800ms RTT)

In this case the RX1 window is not reachable. The RX2 window is also missed, unless the network delay is adjusted.

This is by default with 350ms Network max. delay down:

In this case the RX2 is missed and the TX packet is dropped. The solution is to change the Network max. delay down to a value of 850ms:

The RX1 is not reachable, but the RX2 is, thanks to the updated configuration.

Very bad backhaul (>1000ms)

In this case the RX1 and RX2 windows are never reachable. Indeed, with an example 1200ms RTT, the delay is:

1200 + 350 + 50 + 1200 = 2800ms

The RX2 window has to be changed in order for this to work. On each end device, and on the dashboard configuration of the end device, the RX1 window delay has to be adjusted to a greater value. For example, 2000 (for RX2 target) or 3000ms (for RX1 target) is fine.

Indeed, the delay calculated above is 2800ms, so if RX1 delay is 3000ms, it is reachable.

This is possible at the cost of provisioning every end device on the network so that it can work with high latencies. This can be useful with satellite backhaul, for example.

Edge case: idle cellular radios

Mobile network operators, to save bandwidth and power, usually instruct the mobile equipments to reduce the radio state (RRC layer).

For example, in UMTS, there are mainly three states:

The behavior is that when there is network activity, the mobile is in DCH. When there is no activity, after a delay, the network will place the mobile in FACH. This allows the mobile to quickly recover an active connection (DCH) and to send very limited payloads. When there is still no activity while in FACH, the network will place the mobile in idle state.

When the mobile is idle and wants to send data, it will have to establish a new radio connection to the mobile network, which will take some time. Once in this state (DCH), the mobile will have a low latency.

So basically, if there is no traffic, the first connection may take up to 1000ms. Subsequent connections are faster, like 100 or 200ms.

Solutions

One way to circumvent this is to run a periodic ping on the gateway, this will keep the network connectivity in DCH state with a low latency. The downside is that this generates a lot of data traffic, that may be charged a premium by the mobile ISP.

Another way to work around this is to configure a 1000ms Network max. delay up and a 200ms Network max. delay down. This will allow the LNS to finely compute the delays, and be able to reach the RX2 window.