How can I obtain the EUI from the serial number of my station?

  • iBTS : 7276FF002E<last 6 characters of the CPU serial number>
  • Wirnet Station : 7276FF000<last 7 characters of the station barcode>
  • iFemtoCell : 7276FF0039<last 6 characters of the device board ID>

What is the maximum number of gateways we can define?

  • We can limit the number of gateways, the number of endpoints and number of users linked to a customer via the administration menu (only accessible for users that have SuperAdmin privileges)

What is the maximum number of gateways we can define in the CSV file?

  • There is no limit

When we define a CSV, is it a "add" or a "replacement"?

  • Add

What happens when a mote is already defined in the system and when we try to add it again through the CSV file?

  • An exception is raised and the process stops

What happens when the file embodies a syntax error?

  • An exception is raised and the process stops when the error is encountered. All lines located before this point are taken into account by the system
  • Yes
  • No

I have got a frame counter error (FCnt error). What can I do to cancel this status ?

  • In the LNS / endpoint menu, click on your endpoint and then click to the cross at the right side of the text “FRAME COUNTER DOWN”
  • select F5 for page refresh several times

⇒ Status “Uplink ok” appears and uplink message queue is updated with new messages in “Rx messages” tab

What is the VPN subnet address?

When connected to the Wanesy RAN VPN, the IP address assigned to the gateway is in the 10.8.0.0/16 subnet.

The gateway LAN subnet should not overlap with this subnet.