This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
wiki:firmware:installation [2020/05/13 14:45] mbi [USB] |
wiki:firmware:installation [2023/01/24 14:40] (current) rco [With web interface recommended] |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Wanesy SPN firmware installation ====== | + | ====== Wanesy™ SPN firmware installation from KerOS firmware ====== |
- | By default, Wanesy SPN firmware is not installed on Kerlink gateways. Wanesy SPN can be installed from these versions of KerOS: | + | By default, Wanesy SPN firmware is not installed on Kerlink gateways. Therefore, to install the Wanesy SPN the following steps are required: |
+ | - Check the firmware version of the gateway | ||
+ | - If the firmware is not the expected one, upgrade it | ||
+ | - Upgrade SPN firmware via Web Interface, SSH or by USB | ||
+ | |||
+ | <note important> | ||
+ | Once Wanesy SPN firmware installed, gateway can be configured with web user interface (recommended) or other [[.:..:interfaces:interfaces|interfaces]] | ||
+ | </note> | ||
+ | |||
+ | |||
+ | ===== Firmware version check ===== | ||
+ | |||
+ | Gateway has no default IP address. It is recommended to connect the gateway to a network using a DHCP server. | ||
+ | |||
+ | ==== With web interface "recommended" ==== | ||
+ | |||
+ | * Connect to the web interface of your gateway: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:systeme_mana:webui#connect_to_the_web_interface|click here]] | ||
+ | |||
+ | <note important>For iFemtoCell, web interface password changed between version 3.3.3 and 3.4.3. Products leaving the warehouses could be in different versions. If the default password ''pwd4admin'' does not worked, try ''admin''.</note> | ||
+ | |||
+ | * Once connected to the web interface, go in the overview panel and check the firmware version in the "Information" section. | ||
+ | |||
+ | * Wanesy SPN can be installed from these versions of KerOS: | ||
^ Gateway model ^ KerOS version ^ | ^ Gateway model ^ KerOS version ^ | ||
Line 8: | Line 30: | ||
| **Wirnet iFemtoCell-evolution** | 4.2.1 and above | | | **Wirnet iFemtoCell-evolution** | 4.2.1 and above | | ||
- | Therefore, to install the Wanesy SPN the following steps are required: | ||
- | - Connect to the gateway using SSH | ||
- | - Check the firmware version of the gateway | ||
- | - If the firmware is not the expected one, upgrade it | ||
- | - Upgrade firmware via SSH or by USB | ||
- | <note important> | + | <note warning>Installation of SPN firmware from version 5.X is not possible. You will have to downgrade from 5.X to 4.3.3-2. You can download the firmware 4.3.3-2 on [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:firmware:lastversion#download|this page]]</note> |
- | Once Wanesy SPN firmware installed, gateway can be configured with web user interface (recommended) or other [[.:..:interfaces:interfaces|interfaces]] | + | |
- | </note> | + | |
- | ===== SSH connection ===== | + | * If the firmware is not the expected one, upgrade it. |
+ | *iFemtoCell: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_ifemto#firmware_update_and_configuration|click here]] | ||
+ | *iFemtoCell-evolution: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_ifevo#firmware_update_and_configuration|click here]] | ||
+ | *iStation: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_istation#firmware_update_and_configuration|click here]] | ||
- | Gateway has no default IP address. It is recommended to connect the gateway to a network using a DHCP server. Gateway IP address is needed to connect to it. (Contact your network administrator to get gateway IP address). | + | |
- | - Start a ssh client (for example: TeraTerm or Putty on Windows) | + | ==== With SSH connection ==== |
- | - Connect to the gateway with the following configuration: | + | ++++ click here| |
+ | |||
+ | * Start a ssh client (for example: TeraTerm or Putty on Windows) | ||
+ | * Connect to the gateway with the following configuration: | ||
* address: IP of your gateway | * address: IP of your gateway | ||
* port: ''22'' | * port: ''22'' | ||
Line 32: | Line 53: | ||
{{.:..:images:ifemtocell_label.jpg?400|Board ID can be retrieved on gateway case}} | {{.:..:images:ifemtocell_label.jpg?400|Board ID can be retrieved on gateway case}} | ||
- | ===== KerOS firmware version check ===== | + | * Once connected to the gateway, use the command below to get your firmware version: |
- | + | ||
- | Once connected to the gateway, use the command below to get your firmware version: | + | |
<code bash> | <code bash> | ||
cat /tmp/sys_startup_status.json | grep "sw_version" | cat /tmp/sys_startup_status.json | grep "sw_version" | ||
</code> | </code> | ||
- | An output similar to the following will be displayed: | + | * Wanesy SPN can be installed from these versions of KerOS: |
- | ^ Gateway model ^ KerOS version check ^ | + | ^ Gateway model ^ KerOS version ^ |
- | | **Wirnet iFemtoCell** | ''"sw_version": "3.1.14_20171019161710"'' | | + | | **Wirnet iFemtoCell** | 3.1.14 and above | |
- | | **Wirnet iStation** | ''"sw_version": "4.1.6_20190829151113"'' | | + | | **Wirnet iStation** | 4.1.6 and above | |
- | | **Wirnet iFemtoCell-evolution** | ''"sw_version": "4.2.1_20191209105655"'' | | + | | **Wirnet iFemtoCell-evolution** | 4.2.1 and above | |
- | If the firmware is not the expected one, upgrade it. (Refer to [[https://wikikerlink.fr/wirnet-productline/doku.php|Wirnet Productline wiki]]. Contact [[support@kerlink.fr]] to get access if needed) | + | |
+ | * If the firmware is not the expected one, upgrade it. | ||
+ | *iFemtoCell: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_ifemto#firmware_update_and_configuration|click here]] | ||
+ | *iFemtoCell-evolution: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_ifevo#firmware_update_and_configuration|click here]] | ||
+ | *iStation: [[https://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_istation#firmware_update_and_configuration|click here]] | ||
+ | |||
+ | ++++ | ||
===== Wanesy SPN firmware installation ===== | ===== Wanesy SPN firmware installation ===== | ||
- | The firmware update can be done by SSH or USB | + | The firmware update can be done by Web interface, SSH or USB |
+ | |||
+ | ==== Software update over Web interface "recommended"==== | ||
+ | |||
+ | - Download the firmware from [[wiki:support:resources|Resources]] page. The firmware can be download in the download section of the firmware delivery note. The file is named liveburner_X.X.X-spn_klkgw-signed.ipk. | ||
+ | - Connect to your gateway web interface | ||
+ | - Go in the "Administration" and "Update" Menu | ||
+ | - Drag & drop your SPN ipk file and click on UPDATE GATEWAY. | ||
+ | - A reboot is required to finalize the update, click on REBOOT GATEWAY. | ||
+ | - To use fix IP address check [[https://wikikerlink.fr/wanesy-spn/doku.php?id=wiki:webui:administration:network#ethernet_configuration_fixed_ip_address|Fixed IP]] | ||
+ | |||
+ | <note important> | ||
+ | Upgrade process will take a few minutes and reboot the gateway multiple times. Web user interface will be up and running when the left LED will be lit in green | ||
+ | </note> | ||
- | ==== SSH ==== | + | ==== With SSH connection ==== |
+ | ++++ click here| | ||
- Download the firmware from the [[.:..:support:resources|resources]] page | - Download the firmware from the [[.:..:support:resources|resources]] page | ||
Line 69: | Line 108: | ||
</note> | </note> | ||
- | ==== USB ==== | + | ++++ |
- | === Overview === | + | ==== With USB ==== |
+ | ++++ click here| | ||
+ | |||
+ | **Overview** | ||
- Download the firmware from [[.:..:support:resources|resources]] page | - Download the firmware from [[.:..:support:resources|resources]] page | ||
Line 85: | Line 127: | ||
</note> | </note> | ||
- | === Specific files === | + | **Specific files** |
- | == usbkey.txt == | + | * usbkey.txt |
''usbkey.txt'' is a security file. It includes the password of **usbuser** user. \\ | ''usbkey.txt'' is a security file. It includes the password of **usbuser** user. \\ | ||
Line 107: | Line 150: | ||
</file> | </file> | ||
- | == usb.autorun == | + | * usb.autorun |
''usb.autorun'' is a script automatically executed by the board if the ''usbkey.txt'' file includes a correct password. | ''usb.autorun'' is a script automatically executed by the board if the ''usbkey.txt'' file includes a correct password. | ||
Line 221: | Line 264: | ||
set_led "timer" 100 100 | set_led "timer" 100 100 | ||
</file> | </file> | ||
+ | |||
+ | ++++ | ||
===== Wanesy SPN License installation ===== | ===== Wanesy SPN License installation ===== | ||
Once the Wanesy SPN firmware is running, the license file needs to be installed in order to configure and use the SPN software. The [[.:..:introduction:quickstart|quick start]] page will guide you through these steps. | Once the Wanesy SPN firmware is running, the license file needs to be installed in order to configure and use the SPN software. The [[.:..:introduction:quickstart|quick start]] page will guide you through these steps. |