Table of Contents

Troubleshoot the gateway

Access the log

Two types of logs are available on the gateway:

Logs can be retrieved thanks to:

Public logs

Factory reset

A factory reset can be ordered. This action will:

The factory reset can be triggered thanks to:

Reactivate the Ethernet interface using SMS

The Station and the iFemtocell-Evolution have a SIM card slot that can be used to get a cellular connection.
By default the connection is disabled but the SMS interface is activated, using this interface you can reactivate Ethernet if you have disabled it by error.
you just need to send the following SMS to the phone number of the SIM card in the gateway:

[spn:spnpwd] [coset3] configuration/set_value network.lan.type "dhcp"

the gateway will answer [coset3:ok] if the command is valid.

Then send this SMS:

[spn:spnpwd] [updreb] update/reboot

The gateway will answer [updreb:ok] The gateway will reboot and ethernet connection will be activated on the gateway