User Tools

Site Tools


wiki:firmware:installation

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
wiki:firmware:installation [2020/04/28 09:00]
mbi [Wanesy SPN firmware installation]
wiki:firmware:installation [2023/01/24 14:40] (current)
rco [With web interface recommended]
Line 1: Line 1:
-====== Wanesy SPN firmware installation ======+====== Wanesy™ SPN firmware installation ​from KerOS firmware ​======
  
-By default, Wanesy SPN firmware is not installed on Kerlink gateways. Wanesy SPN can be installed from these versions of KerOS:+By default, Wanesy SPN firmware is not installed on Kerlink gateways. ​Therefore, to install the Wanesy SPN the following steps are required: 
 +  - Check the firmware version of the gateway 
 +  - If the firmware is not the expected one, upgrade it 
 +  - Upgrade SPN firmware via Web Interface, SSH or by USB 
 + 
 +<note important>​ 
 +Once Wanesy SPN firmware installed, gateway can be configured with web user interface (recommended) or other [[.:​..:​interfaces:​interfaces|interfaces]] 
 +</​note>​ 
 + 
 + 
 +===== Firmware version check ===== 
 + 
 +Gateway has no default IP address. It is recommended to connect the gateway to a network using a DHCP server.  
 + 
 +==== With web interface "​recommended"​ ==== 
 + 
 +  * Connect to the web interface of your gateway: [[https://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​systeme_mana:​webui#​connect_to_the_web_interface|click here]] 
 + 
 +<note important>​For iFemtoCell, web interface password changed between version 3.3.3 and 3.4.3. Products leaving the warehouses could be in different versions. If the default password ''​pwd4admin''​ does not worked, try ''​admin''​.</​note>​  
 + 
 +  * Once connected to the web interface, go in the overview panel and check the firmware version in the "​Information"​ section. 
 + 
 +  * Wanesy SPN can be installed from these versions of KerOS:
  
 ^ Gateway model                   ^ KerOS version ​   ^ ^ Gateway model                   ^ KerOS version ​   ^
Line 8: Line 30:
 | **Wirnet iFemtoCell-evolution** | 4.2.1 and above  | | **Wirnet iFemtoCell-evolution** | 4.2.1 and above  |
  
-Therefore, to install the Wanesy SPN the following steps are required: 
-  - Connect to the gateway using SSH 
-  - Check the firmware version of the gateway 
-  - If the firmware is not the expected one, upgrade it 
-  - Upgrade firmware via SSH or via USB 
  
-<​note ​important> +<​note ​warning>Installation of SPN firmware ​from version 5.X is not possible. You will have to downgrade from 5.X to 4.3.3-2. You can download the firmware 4.3.3-2 on [[https://​wikikerlink.fr/​wirnet-productline/​doku.php?id=wiki:firmware:lastversion#​download|this page]]</​note>​
-Once Wanesy ​SPN firmware ​installed, gateway ​can be configured with web user interface (recommended) or other [[.:..:interfaces:interfaces|interfaces]] +
-</​note>​+
  
-===== SSH connection =====+  * If the firmware is not the expected one, upgrade it.  
 +    *iFemtoCell:​ [[https://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​quickstart:​quickstart_ifemto#​firmware_update_and_configuration|click here]] 
 +    *iFemtoCell-evolution:​ [[https://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​quickstart:​quickstart_ifevo#​firmware_update_and_configuration|click here]] 
 +    *iStation: [[https://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​quickstart:​quickstart_istation#​firmware_update_and_configuration|click here]]
  
-Gateway has no default IP address. It is recommended to connect the gateway to a network using a DHCP server. Gateway IP address is needed to connect to it. (Contact your network administrator to get gateway IP address). + 
-  ​Start a ssh client (for example: TeraTerm or Putty on Windows) +==== With SSH connection ==== 
-  ​Connect to the gateway with the following configuration:​+++++ click here| 
 + 
 +  ​Start a ssh client (for example: TeraTerm or Putty on Windows) 
 +  ​Connect to the gateway with the following configuration:​
      * address: IP of your gateway ​            * address: IP of your gateway ​      
      * port: ''​22''​      * port: ''​22''​
Line 32: Line 53:
 {{.:​..:​images:​ifemtocell_label.jpg?​400|Board ID can be retrieved on gateway case}} {{.:​..:​images:​ifemtocell_label.jpg?​400|Board ID can be retrieved on gateway case}}
  
-===== KerOS firmware version check ===== +  * Once connected to the gateway, use the command below to get your firmware version:
- +
-Once connected to the gateway, use the command below to get your firmware version:+
 <code bash> <code bash>
 cat /​tmp/​sys_startup_status.json | grep "​sw_version"​ cat /​tmp/​sys_startup_status.json | grep "​sw_version"​
 </​code>​ </​code>​
  
-An output similar to the following will be displayed+  * Wanesy SPN can be installed from these versions of KerOS:
  
-^ Gateway model                   ^ KerOS version ​check   +^ Gateway model                   ^ KerOS version ​   
-| **Wirnet iFemtoCell** ​          ​| ​''"​sw_version":​ "3.1.14_20171019161710"'' ​+| **Wirnet iFemtoCell** ​          | 3.1.14 and above 
-| **Wirnet iStation** ​            ​| ​''"​sw_version":​ "4.1.6_20190829151113"'' ​+| **Wirnet iStation** ​            | 4.1.6 and above  ​
-| **Wirnet iFemtoCell-evolution** | ''"​sw_version":​ "4.2.1_20191209105655"'' ​|+| **Wirnet iFemtoCell-evolution** | 4.2.1 and above  ​|
  
-If the firmware is not the expected one, upgrade it. (Refer to [[https://​wikikerlink.fr/​wirnet-productline/​doku.php|Wirnet Productline ​wiki]]. ​Contact ​[[support@kerlink.fr]] to get access if needed)+ 
 +  * If the firmware is not the expected one, upgrade it.  
 +    *iFemtoCell: ​[[https://​wikikerlink.fr/​wirnet-productline/​doku.php?id=wiki:​quickstart:​quickstart_ifemto#​firmware_update_and_configuration|click here]] 
 +    *iFemtoCell-evolution:​ [[https://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​quickstart:​quickstart_ifevo#​firmware_update_and_configuration|click here]] 
 +    *iStation: ​[[https://​wikikerlink.fr/​wirnet-productline/​doku.php?​id=wiki:​quickstart:​quickstart_istation#​firmware_update_and_configuration|click here]] 
 + 
 +++++
  
 ===== Wanesy SPN firmware installation ===== ===== Wanesy SPN firmware installation =====
  
-The firmware update can be done by SSH or USB+The firmware update can be done by Web interface, ​SSH or USB 
 + 
 +==== Software update over Web interface "​recommended"​==== 
 + 
 +  - Download the firmware from [[wiki:​support:​resources|Resources]] page. The firmware can be download in the download section of the firmware delivery note. The file is named liveburner_X.X.X-spn_klkgw-signed.ipk.  
 +  - Connect to your gateway web interface 
 +  - Go in the "​Administration"​ and "​Update"​ Menu 
 +  - Drag & drop your SPN ipk file and click on UPDATE GATEWAY.  
 +  - A reboot is required to finalize the update, click on REBOOT GATEWAY. 
 +  - To use fix IP address check [[https://​wikikerlink.fr/​wanesy-spn/​doku.php?​id=wiki:​webui:​administration:​network#​ethernet_configuration_fixed_ip_address|Fixed IP]] 
 + 
 +<note important>​ 
 +Upgrade process will take a few minutes and reboot the gateway multiple times. Web user interface will be up and running when the left LED will be lit in green 
 +</​note>​
  
-==== SSH ====+==== With SSH connection ​==== 
 +++++ click here|
  
   - Download the firmware from the [[.:​..:​support:​resources|resources]] page   - Download the firmware from the [[.:​..:​support:​resources|resources]] page
Line 69: Line 108:
 </​note>​ </​note>​
  
-==== USB ====+++++
  
-=== Overview ​===+==== With USB ==== 
 +++++ click here| 
 + 
 +**Overview**
  
   - Download the firmware from [[.:​..:​support:​resources|resources]] page   - Download the firmware from [[.:​..:​support:​resources|resources]] page
Line 85: Line 127:
 </​note>​ </​note>​
  
-=== Specific files ===+**Specific files** 
  
-== usbkey.txt ​==+  * usbkey.txt
  
 ''​usbkey.txt''​ is a security file. It includes the password of **usbuser** user. \\ ''​usbkey.txt''​ is a security file. It includes the password of **usbuser** user. \\
Line 96: Line 139:
 Here is an example of this file for 4 boards (010001 / 020056 / 040001 / 092356): \\ Here is an example of this file for 4 boards (010001 / 020056 / 040001 / 092356): \\
 First board has a generic password and 3 others have a "​serial-based"​ modified password ("<​serial>​_usbkey"​) \\ First board has a generic password and 3 others have a "​serial-based"​ modified password ("<​serial>​_usbkey"​) \\
 +
 +Link below to download usbkey.txt file 
 +
 <file text usbkey.txt>​ <file text usbkey.txt>​
 USBklkPassword USBklkPassword
Line 104: Line 150:
 </​file>​ </​file>​
  
-== usb.autorun ​==+  * usb.autorun
  
 ''​usb.autorun''​ is a script automatically executed by the board if the ''​usbkey.txt''​ file includes a correct password. ​ ''​usb.autorun''​ is a script automatically executed by the board if the ''​usbkey.txt''​ file includes a correct password. ​
 The following script is used to deploy the Wanesy SPN firmware. Copy this script in a file named ''​usb.autorun''​. The following script is used to deploy the Wanesy SPN firmware. Copy this script in a file named ''​usb.autorun''​.
 +
 +Link below to download usb.autorun file
  
 <file bash usb.autorun>​ <file bash usb.autorun>​
Line 216: Line 264:
 set_led "​timer"​ 100 100 set_led "​timer"​ 100 100
 </​file>​ </​file>​
 +
 +++++
  
 ===== Wanesy SPN License installation ===== ===== Wanesy SPN License installation =====
  
 Once the Wanesy SPN firmware is running, the license file needs to be installed in order to configure and use the SPN software. The [[.:​..:​introduction:​quickstart|quick start]] page will guide you through these steps. Once the Wanesy SPN firmware is running, the license file needs to be installed in order to configure and use the SPN software. The [[.:​..:​introduction:​quickstart|quick start]] page will guide you through these steps.
wiki/firmware/installation.1588057216.txt.gz · Last modified: 2020/04/28 09:00 by mbi