- | ====== Wirnet™ iFemtoCell installation recommendations ====== | ||
- | The detailed installation procedure is described in the "Installation and maintenance manual" available from the [[resources_ibts:resources#wirnet_ibts_installation_and_maintenance|resources]] page. This procedure must be read, the integrity of the gateway, its warranty and its efficiency depend on it. | ||
- | |||
- | Here are the key factors of a good installation (it does not prevent you from reading the "Installation and maintenance manual"), plus a few additional recommendations:\\ | ||
- | FIXME | ||
- | * In harsh environment, especially if antenna link (LoRa) is placed in outdoor conditions, RF coaxial surge protection must be used. | ||
- | * In harsh environment, especially if Ethernet link is placed in outdoor conditions, an indoor Ethernet surge protection must be used. | ||
- | * A good earthing of the whole installation is required. | ||
- | * Used ground connection cables must be as short as possible (<30cm, 4sq.mm). | ||
- | * It is recommended to regroup all ground connections at one point (at least mounting bracket + surge protections). This point must be as close as possible to the product. | ||
- | * Recommended shielding Ethernet cable is category 6A, STP or SSTP. | ||
- | * Before any product installation, a full spectrum analysis should be done on the field with a spectrum analyzer. A backup of each measurement is strongly recommended in case further analysis is required. | ||
- | * Photos of the full installation are also recommended to memorize antennas co-locations and check if the installation is properly done. |