This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
|
wiki:systeme_mana:features [2019/09/25 15:38] ghi created |
wiki:systeme_mana:features [2025/09/09 10:39] (current) ehe [Manual Stock restore] |
||
|---|---|---|---|
| Line 11: | Line 11: | ||
| This feature cannot be disabled as it avoids bricking the gateway in case of software failure. | This feature cannot be disabled as it avoids bricking the gateway in case of software failure. | ||
| - | The counter ''bootfail'' is displayed at boot time only if the reboot is due to a watchdog. Bootcause information are available [[wiki:troubleshoot#bootcause|here]]. | + | The counter ''bootfail'' is displayed at boot time only if the reboot is due to a watchdog. Bootcause information are available [[wiki:support:troubleshoot#bootcause|here]]. |
| ++++ | ++++ | ||
| Line 49: | Line 49: | ||
| - | Modifications in rootfs will be lost except [[wiki:upgrade#configuration_management_sysupgrade|system upgrade]] files. | + | Modifications in rootfs will be lost except [[wiki:keros_custo:upgrade#configuration_management_sysupgrade|system upgrade]] files. |
| This mecanism is divided in 2 elements: | This mecanism is divided in 2 elements: | ||
| Line 77: | Line 77: | ||
| \\ | \\ | ||
| ==== Manual Stock restore ==== | ==== Manual Stock restore ==== | ||
| - | Since firmware >= 4.1, a "stock restore" can also be triggered manually without console access. \\ | ||
| - | To manually trigger a stock restore on Wirnet **iBTS** or **iStation**, please follow this procedure: | ||
| - | - Unpower the gateway by pushing ON/OFF button more than 5 seconds | ||
| - | - Make sure [[wiki:peripherals#leds|Power led]] is off and release button | ||
| - | - Push On/OFF button to power-up the gateway and maintain until power and status leds blink alternatively. At this step, the gateway is ready to execute a stock restore operation. It will wait for a confirmation during 10 seconds | ||
| - | - Release button and push it again to confirm the operation (leds will then stop blinking alternatively) | ||
| - | - Wait for the end of this operation (Leds behavior described [[wiki:peripherals#leds|here]]). It takes approximately 2 minutes | ||
| - | To manually trigger a stock restore on Wirnet **iFemtocell**, please follow this procedure: | + | Since firmware >= 4.1, a "stock restore" can also be triggered manually without console access. |
| - | - Push WPS button and maintain it | + | |
| - | - Push Reset button one second | + | |
| - | - At this step, the gateway is ready to execute a stock restore operation. It will wait for a confirmation during 10 seconds | + | |
| - | - Release WPS button and push it again to confirm the operation (leds will then stop blinking alternatively) | + | |
| - | - Wait for the end of this operation (Leds behavior described [[wiki:peripherals#leds|here]]). It takes approximately 2 minutes | + | |
| - | \\ \\ | + | ++++ |
| + | To manually trigger a stock restore on Wirnet iBTS, Wirnet iStation, Wirnet iFemtocell, Wirnet iFemtoCell-evolution, please follow this procedure:| | ||
| + | - Turn off your gateway. | ||
| + | - Press and hold the ON/OFF button (use the WPS button for iFemtoCell). | ||
| + | - Turn the power back on and wait a couple of seconds (the LEDs should blink fast). | ||
| + | - Release the button and click it once. | ||
| + | - Wait for the end of this operation (Leds behavior described [[wiki:systeme_mana:peripherals#leds|here]]). It takes approximately 2 minutes. | ||
| + | ++++ | ||
| + | |||
| + | ++++ | ||
| + | To manually trigger a stock restore on Wirnet iZeptoCell, please follow this procedure:| | ||
| + | - Press the button once to trigger a software reset | ||
| + | - Push the button again when the status led is blinking red and maintain until power and status leds blink alternatively. At this step, the gateway is ready to execute a stock restore operation. It will wait for a confirmation during 10 seconds. | ||
| + | - Release button and push it again to confirm the operation (leds will then stop blinking alternatively). | ||
| + | - Wait for the end of this operation (Leds behavior described [[wiki:systeme_mana:peripherals#leds|here]]). It takes approximately 2 minutes. | ||
| + | ++++ | ||
| + | \\ | ||
| ===== Store & Restore configuration ===== | ===== Store & Restore configuration ===== | ||
| - | This functionality from firmware < 4.0 must not be used to store configuration files. In order to save configuration use the [[wiki:upgrade#configuration_management_sysupgrade|sysupgrade]] management. | + | This functionality from firmware < 4.0 must not be used to store configuration files. In order to save configuration use the [[wiki:keros_custo:upgrade#configuration_management_sysupgrade|sysupgrade]] management. |