 ==== Manual Stock restore ==== ==== Manual Stock restore ====
-Since firmware >= 4.1, a "stock restore"​ can also be triggered manually without console access. \\ 
-To manually trigger a stock restore on a Wirnet gateway (excepting iFemtocell),​ please follow this procedure: 
-  - Unpower the gateway by pushing ON/OFF button more than 5 seconds. 
-  - Make sure [[wiki:​systeme_mana:​peripherals#​leds|Power led]] is off and release button. 
-  - Push On/OFF button to power-up the gateway and maintain until power and status leds blink alternatively. At this step, the gateway is ready to execute a stock restore operation. It will wait for a confirmation during 10 seconds. 
-  - Release button and push it again to confirm the operation (leds will then stop blinking alternatively). 
-  - Wait for the end of this operation (Leds behavior described [[wiki:​systeme_mana:​peripherals#​leds|here]]). It takes approximately 2 minutes. 
  
-This procedure works for all Wirnet gateways excepting Wirnet iFemtocell which doesn'​t have an ON/OFF button.+Since firmware >= 4.1, a "stock restore"​ can also be triggered manually without console access.
  
 ++++ ++++
-To manually trigger a stock restore on Wirnet iFemtocell, please follow this procedure:​| +To manually trigger a stock restore on Wirnet iBTS, Wirnet iStation, ​Wirnet iFemtocell, Wirnet iFemtoCell-evolution, please follow this procedure:​| 
-  - Push WPS button and maintain it+  - Turn off your gateway
-  - Push Reset button ​one second+  - Press and hold the ON/​OFF ​button ​(use the WPS button for iFemtoCell)
-  - At this step, the gateway is ready to execute a stock restore operation. It will wait for confirmation during 10 seconds. +  - Turn the power back on and wait a couple of seconds ​(the LEDs should blink fast)
-  - Release ​WPS button and push it again to confirm the operation (leds will then stop blinking alternatively).+  - Release ​the button and click it once
   - Wait for the end of this operation (Leds behavior described [[wiki:​systeme_mana:​peripherals#​leds|here]]). It takes approximately 2 minutes.   - Wait for the end of this operation (Leds behavior described [[wiki:​systeme_mana:​peripherals#​leds|here]]). It takes approximately 2 minutes.
 ++++ ++++
  
 +++++
 +To manually trigger a stock restore on Wirnet iZeptoCell, please follow this procedure:|
 +  - Press the button once to trigger a software reset
 +  - Push the button again when the status led is blinking red and maintain until power and status leds blink alternatively. At this step, the gateway is ready to execute a stock restore operation. It will wait for a confirmation during 10 seconds.
 +  - Release button and push it again to confirm the operation (leds will then stop blinking alternatively).
 +  - Wait for the end of this operation (Leds behavior described [[wiki:​systeme_mana:​peripherals#​leds|here]]). It takes approximately 2 minutes.
 +++++
 \\ \\
 ===== Store & Restore configuration ===== ===== Store & Restore configuration =====
  
 This functionality from firmware < 4.0 must not be used to store configuration files. In order to save configuration use the [[wiki:​keros_custo:​upgrade#​configuration_management_sysupgrade|sysupgrade]] management. This functionality from firmware < 4.0 must not be used to store configuration files. In order to save configuration use the [[wiki:​keros_custo:​upgrade#​configuration_management_sysupgrade|sysupgrade]] management.