iFemtoCell SPN firmware v2.0.3 (April 2018)

Breaking of compatibility: license files

Due to the evolution of Wanesy SPN V2 software, licensing management modification leads to a break of compatibility with the license management of Wanesy SPN V1.

Wirnet iFemtoCell Wanesy SPN firmware v2 must only be activated by a valid Wanesy SPN V2 license file.

Wanesy SPN license file provided with SPN version V1 will not allow to run the Wanesy SPN v2 version, even if the V2 firmware can be installed (locked waiting V2 license).

Please contact sales@kerlink.com to order SPN V2 licenses before upgrading to Wirnet iFemtoCell SPN firmware v2.

License files SPN V2 are not compatible with Wirnet iFemtoCell SPN firmware V1 (v1.0.3 and V1.1.1).

Changes from 1.1.1

New features

  • [LoRa] Listen Before Talk (LBT) for Japan and Korea.
  • [Multi-gateways]: SPN can now receive/send LoRa frames from/to other SPN iFemtoCell, Wirnet station and Wirnet iBTS.
  • [SMS interface]: New interface to : get Rx data, add Tx data, manage configuration, manage end-devices, update interface activation, manage gateways, get status, update confguration file.
  • [System]: Retrieve send Tx data.
  • [System]: Delete end-device fleet.
  • [System]: Add OpenVPN.
  • [System]: Add halt command (with restrictions).
  • [System]: Reset configuration .
  • [LOCAL FTP interface]: License management.
  • [WEB interface]:End-device parameters edition.
  • [WEB interface]: Download Open-VPN configuration.
  • [USB interface]: Add Tx data withUSB key command.

Evolutions

  • [LOCAL FTP interface]: The status file names now contain a OK/KO status.
  • [USB interface]: The status file names now contain a OK/KO status.
  • [USB interface]: move XXXXXXXX_password file.
  • [System]: Remove rx2_frequency and rx2_datarate parameters from configuration.
  • [System]: Change Tx data field order.
  • [System]: Serial number now with 8 digits.
  • [system]: LED behavior.
  • [System]: Update license file format.
  • [System]: Shut down WiFi administration interface after 1 hour.

Restrictions

  • [System]: Wirnet iFemtoCell SPN pass on WiFi connection only if we unplug the ethernet wire.
  • [System]: Cannot declare an OTAA end-device starting with multiple 0 (e.g. 0000000000112233) if an ABP end-device has the same name (00112233).
  • [System]: End-devices sequence numbers are reset if the end-devices are restarted.
  • [System]: getOpenVPNConfiguration returns only “enable”.
  • [System]: Halt on iFemtoCell SPN doesn't really stop the iFemtoCell. It reboots after a few seconds/minutes.
  • [System]: Region configuration lost between version 1.1.1 and 2.0.0 for US gateways.
  • [System]: Status is always “UNKNOWN” in the fleet.
  • [System]: Cannot create end-device immediately after a switch from region Australia 915-928 to AS 923MHz.
  • [System]: Received data are not correctly formated (no zero padding).
  • [System]: When switched off, the WiFi radio power is not truly powered off.
  • [LoRa]: Change of network_id do not reject frames of a mote that don't perform a new join.
  • [LoRa]: FSK is not supported with data rate 7.
  • [LoRa]: DR6 SF7-BW250 for RX2 data rate is not available for Asia and Japan Region.
  • [LoRa]: MonoSF drift from radio x central frequency is reduce from 400kHz to 300kHz.
  • [LoRa]: Possible to set Tx power higher than 23 dBm in Korea Rrgion.
  • [Remote HTTP]: The push URL cannot contain any question mark sign, has to end with a slash, and it always has a suffix appended to what the user has entered.
  • [WEB interface]: When the timezone is changed, a reboot is needed to apply the configuration in the log files.
  • [WEB interface]: Network parameters are lost when a network interface is turned off on WEB interface.
  • [WEB interface]: Reset configuration is too slow, nothing happens before 30s - 60s.

Compatibility

Hardware

  • No known issues on various hardware product versions.

Software

  • Compatible with Wirnet iFemtocell firmware, from version 3.0.0..
  • Compatible with Wirnet iFemtocell/SPN firmware version 1.0.3 and 1.1.1.

Download

For SPN new installation only (no SPN firmware installed):
liveburner_2.0.3-spn_klk-wifc.ipk md5: e1bd24ba904baba5020d3d2f1a236950.

For SPN upgrade only (SPN firmware already installed):
keros_2.0.3-spn_klk-wifc.ipk md5:14ce5c413c0adaa826fe39872a749358

For SPN reinstallation and reset (SPN 2.0.3 firmware already installed):
liveburner_2.0.3-spn_klk-wifc.ipk.gpg md5:616c6befac9c53d7e35b87bfdb5cbd81

wiki/resources_spn_firmware_2.0.3.1525706526.txt.gz · Last modified: 2020/02/21 11:53 (external edit)