Introduction

An SMS interface is available on SPN gateways. It can be used to:

  • Configure the gateway.
  • Configure the end-devices fleet.
  • Configure the gateways fleet.
  • Add license.
  • Debug / troubleshoot the gateway.

SMS Command - Syntax

The command syntax is also described in the web interface under the Help section in the SMS utils tab from the interface menu.

SMS request

[spn:spnpwd] [cmdid1] flow/command

spn: SPN user, always spn.
spnpwd: SPN password.
cmdid1: command identifier used for response. Must be alphanumeric characters in lower case, 6 digits.
flow: group of command (end_device, gateway, rx_data, tx_data, configuration, update or status).
command: command to run, depending on flow.

SMS answer

Correct request:

[cmdid1:ok] answer

cmdid1: command identifier passed in request.
answer: the answer of the request, format depends on the request.

Incorrect request:

[cmdid1:error] error message

cmdid1: command identifier passed in request.
error message: error message indicating what goes wrong.

SMS features

Before starting to work with the SMS manager, make sure to:

  • For iFemtocell: plug an USB GSM dongle.
  • Retrieve the SIM phone number used by the USB GSM Dongle.

End-device fleet flow

Add ABP end-device:

[spn:spnpwd] [endadd] end_device/add_end_device end_device_csv

end_device_csv: syntax can be retrieved by downloading the template from the web interface.
Example:

[spn:spnpwd] [endadd] end_device/add_end_device ABP,C,,,,11223344,11112222333344445555666677778888,11112222333344445555666677778888,255,869525000,0

Add OTAA end-device:

[spn:spnpwd] [endadd] end_device/add_end_device end_device_csv

end_device_csv: syntax can be retrieved by downloading the template from the web interface.
Example:

[spn:spnpwd] [endadd] end_device/add_end_device OTAA,C,1122334455667788,1122334455667788,11112222333344445555666677778888,,,,255,869525000,0

Delete ABP end-device:

[spn:spnpwd] [enddel] end_device/delete_end_device dev_addr

dev_addr: ABP device address (8 hexadecimal digits in upper case).
Example:

[spn:spnpwd] [enddel] end_device/delete_end_device 11223344

Delete OTAA end-device:

[spn:spnpwd] [enddel] end_device/delete_end_device dev_eui

dev_eui: OTAA device EUI (16 hexadecimal digits in upper case).
Example:

[spn:spnpwd] [enddel] end_device/delete_end_device 1122334455667788

Delete end-device fleet:

[spn:spnpwd] [enddef] end_device/delete_fleet

Gateway fleet flow

Add gateway:

[spn:spnpwd] [gatadd] gateway/add_gateway gateway_csv

gateway_csv: syntax can be retrieved by downloading the template from the web interface.
Example:

[spn:spnpwd] [gatadd] gateway/add_gateway 7276FF0039020003

Delete gateway:

[spn:spnpwd] [gatdel] gateway/delete_gateway gateway_id

gateway_id: gateway identifier (16 hexadecimal digits in upper case).
Example:

[spn:spnpwd] [gatdel] gateway/delete_gateway 7276FF0039020003

Delete gateway fleet:

[spn:spnpwd] [gatdef] gateway/delete_fleet

Rx data flow

Get Rx data from ABP end-device:

[spn:spnpwd] [rxdget] rx_data/get_rx_data dev_addr

dev_addr: ABP device address (8 hexadecimal digits in upper case).
Example:

[spn:spnpwd] [rxdget] rx_data/get_rx_data 11223344

SMS answer contains Rx data in CSV, syntax can be retrieved by downloading the template from the web interface.

Get Rx data from OTAA end-device:

[spn:spnpwd] [rxdget] rx_data/get_rx_data dev_eui

dev_eui: OTAA device EUI (16 hexadecimal digits in upper case).
Example:

[spn:spnpwd] [rxdget] rx_data/get_rx_data 1122334455667788

SMS answer contains Rx data in CSV, syntax can be retrieved by downloading the template from the web interface.

Tx data flow

Add Tx data to ABP or OTAA end-device:

[spn:spnpwd] [txdadd] tx_data/add_tx_data tx_data_csv

tx_data_csv: syntax is described through DOWNLOAD button.
Example:

[spn:spnpwd] [txdadd] tx_data/add_tx_data 11223344,2,true,5,MDAyN2JkMDlkMGZlOWMzYTAwMDAwMDAwMDAwMGZmZmY=

Configuration flow

Whole configuration is described can be retrieved by downloading the template from the web interface.

Sample of configuration file:

{
  "body": {
    "public": {
      "loftp": {
        "enable": false
      }
    }
  }
}

In this sample, parameter path is loftp.enable.

Get parameter:

[spn:spnpwd] [conget] configuration/get_value parameter_path

parameter_path: parameter path.
Example:

[spn:spnpwd] [conget] configuration/get_value loftp.enable

Set boolean parameter:

[spn:spnpwd] [coset1] configuration/set_value boolean_parameter_path value

boolean_parameter_path: boolean parameter path.
value: true of false.
Example:

[spn:spnpwd] [coset1] configuration/set_value loftp.enable true

Set number parameter:

[spn:spnpwd] [coset1] configuration/set_value number_parameter_path value

number_parameter_path: number parameter path.
value: a number.
Example:

[spn:spnpwd] [coset2] configuration/set_value csvlo.rotation_count 55

Set string parameter

[spn:spnpwd] [coset1] configuration/set_value string_parameter_path value

string_parameter_path: string parameter path.
value: a string in double quotes.

Example:

[spn:spnpwd] [coset3] configuration/set_value csvlo.rotation_time "hour"

Reset configuration:

[spn:spnpwd] [conres] configuration/reset

Update flow

Add license:

[spn:spnpwd] [updadd] update/add_license license_content

license_content: content of license file provided.
Example:

[spn:spnpwd] [updadd] update/add_license -----BEGIN SIGNATURE-----\nsmzmFH2J/tRteB62kkush427wKKE/ahM1ojCZukDlE2lGrR28QxPtKlBhoR9p0nc\nwm8uk1xFBlgj+x/1TmkxaRIkXJkQTqkUbvzsoe4omcPvgfjfTu3FiAiN3NkixCHw\nh6ehOilCNQvCiKTe8kWaO/Bx+jX+Pt4kmdpTMMch02dxisCNobAqPbzRq31ElH81\naa9nUgrcA4iqett5AowAcKfIPHIo6hTHvlGnmOhA7vN7IN9vdgtvTDEFclwxfbmU\nPqmqOVlXHfaaLV/Crn/R7wfkKjOPmEp3vaK0u2GkELzw0sQUzpkEMhJF2sN67ovd\ntDFUCNi54R5ziCmLMvko2A==\n-----END SIGNATURE-----\n-----BEGIN ICENSE-----\n[license]\nhardware_serial_number = 3903001D\nexpiration_date = 1540123200\ngateways_max_number = 10\nend_devices_max_number = 0\n-----END LICENSE-----

Restore:

[spn:spnpwd] [updres] update/restore

Reboot:

[spn:spnpwd] [updreb] update/reboot

Halt:

[spn:spnpwd] [updhal] update/halt

Status flow

Get status:

[spn:spnpwd] [staget] status/get_status