The gateway cannot listen to all frequencies simultaneously. Up to 8 frequencies can be configured in Configuration ⇒ Rx configuration ⇒ Rx configuration
.
To understand how the frequency configuration works, it is necessary to know that the Wirnet gateway hardware contains two RF front-ends. Each of these front-ends has a 0.8 MHz Bandwidth. Thus, all 8 channels must be contained within these two 0.8 MHz intervals.
To properly configure the Rx channels, the center frequencies of the front-ends must be defined.
Once the center frequencies are defined, each channel can be configured.
Here are a few rules/information to configure the frequencies:
Example of a typical configuration for 868MHz band (868.1MHz, 868.3MHz and 868.5MHz are mandatory in most countries using 868MHz end-devices):
Example of all 8 frequencies contained within one 0.8MHz interval: