- | ====== Wirnet™ iFemtocell-Evolution installation recommendations ====== | + | ====== Wirnet™ iFemtocell-evolution installation recommendations ====== |
- | The installation procedure is described in the quickstart guide delivered with your gateway (also available in [[wiki:resources:resources#documentation|resources]]). This procedure must be read, the integrity of the gateway, its warranty and its efficiency depend on it. | + | Installation of a LoRaWAN gateway shall be carefully prepared in advance to anticipate the future coverage area, QoS and make sure that all needed equipment’s are listed and are available the D-day but also to be sure that the installation is conformed to the Kerlink recommendations : {{ :documentation:an-klk03357_-_lorawan_gateways_installation_recommendations_-_v1.2.pdf | Gateways installation recommendations}}. |
+ | |||
+ | <note warning> | ||
+ | WARNING: LoRa signal output power on Wirnet iFemtoCell-evolution | ||
+ | |||
+ | * The Wirnet iFemtoCell-evolution conducted output power must be adjusted from 0dBm to +24dBm. | ||
+ | * To avoid shortening the life of the equipment, output conducted power must be strictly limited to 24dBm (out of the SMA/RP-SMA connector) corresponding to a 27dBm EIRP output power (with the 3dBi antenna gain).\\ | ||
+ | * Customer is responsible for ensuring the correct management of power output by a third party Lora Network Server (LNS) or custom applications.\\ | ||
+ | * This design constraint is induced by the LoRa radio and the embedded LTE telecom modem cohabitation.\\ | ||
+ | |||
+ | Maximum LoRa signal output power is limited to 24dBm in the calibration file ''/tmp/calib_rf.json''.\\ | ||
+ | The [[wiki:lora:cpf|Kerlink Common Packet Forwarder (CPF)]] and [[http://wikikerlink.fr/wanesy-ran/doku.php|Kerlink Wanesy Management Center]] respect this constraint. | ||
+ | |||
+ | </note> | ||
+ | |||
+ | The installation procedure is described in the quickstart guide delivered with your gateway (also available in [[wiki:quickstart:quickstart_ifevo#documentation|the setup page]]). This procedure must be read, the integrity of the gateway, its warranty and its efficiency depend on it. | ||
In order to optimize gateway performances and protection, please refer to application notes in [[wiki:resources:resources#documentation|documentation section of resources]]. | In order to optimize gateway performances and protection, please refer to application notes in [[wiki:resources:resources#documentation|documentation section of resources]]. | ||
Line 13: | Line 28: | ||
* Before any product installation, a full spectrum analysis should be done on the field with a spectrum analyzer. A backup of each measurement is strongly recommended in case further analysis is required. | * Before any product installation, a full spectrum analysis should be done on the field with a spectrum analyzer. A backup of each measurement is strongly recommended in case further analysis is required. | ||
* Photos of the full installation are also recommended to memorize antennas co-locations and check if the installation is properly done. | * Photos of the full installation are also recommended to memorize antennas co-locations and check if the installation is properly done. | ||
+ | * The wirnet iFemtoCell-evolution conducted output power must be adjusted from 0dBm to +24dBm. |