KerOS firmware v5.10.1 (October 2023)

Changes from v5.9.0

Release corrections

  • Fix missing channels in LoRaWAN radio configuration
  • Enable LoRaWAN radio configuration by Basic Station on iZepto-cell products
  • Monitor temperature range at LoRa service start
  • Reduce RAM consumption caused by internal databases

Evolutions

  • Add the possibility to use HTTPS for the Web User Interface
  • Support of EC25J auto-Fuota

Restrictions

  • IPSec is not yet supported
  • Some issues with the Wi-Fi interface (instabilities, no fallback…) on Wirnet iFemtoCell
  • When upgrading from KerOS firmware 4.x, all trustzone secrets are lost
  • When upgrading from KerOS FW 4.3.3, a hardware reset is necessary for FW 5.x burner to correctly detect USB
  • Update status for an update from KerOS FW 5.1.x, FW 5.2.x or FW 5.3.x is in error, but the update is working fine
  • No more support of GSM dongles (please contact Kerlink if you plan to use one)
  • When iZepto-E is powered by a computer, it cannot benefit from the connection of a gateway in router mode
  • The activation/deactivation of the GSM from the local web interface takes some time to execute, so previous activation status remains displayed for a while. A page refresh after a delay of 15-20s after the action shows the right status

Firmware

Compatibility

  • Compatible with Wirnet™ i-series gateways (Wirnet iBTS, Wirnet iFemtoCell, Wirnet iStation, Wirnet iFemtoCell-evolution, Wirnet iZeptoCell Ethernet, Wirnet iZeptoCell Cellular).

Software

  • Compatible with Wirnet™ i-series gateways secured with Kerlink Production fuses or without any fuses flashed.
  • Regular update (keros.ipk) is incompatible with firmware older than v5.x

  • To upgrade the system from KerOS version 4.3.3 to KerOS version 5.x the use of a liveburner is MANDATORY. Two possibilities are available:
  • Upgrade with a custom liveburner. It allows to keep some elements like gateway configuration. To use a custom liveburner, please refer to the dedicated page: Major version upgrade with a custom liveburner.
  • Upgrade with a regular liveburner (erasing the whole partition to reinstall the firmware)

Delivery

The firmware is released in two formats: KerOS and Liveburner.

KerOS : Update the Firmware
To update the firmware from v5.x, the regular update procedure can be used. See system upgrade page.


Liveburner : Reset the Firmware of the product

  • Update stock version with FW 5.10.1.
  • Reset the default password on your gateway.
  • Erase the whole partition to reinstall the firmware.