KerOS firmware v5.12.0 (November 2025)

Changes from v5.11.0

Release corrections

  • Lighten some unnecessary logs which were in verbose mode
  • Prevent Basic Station and lorad from restarting each other in loop

Evolutions

    • CVE-2024-32384
    • CVE-2024-39148
    • CVE-2024-32388
  • Remove LNS credentials from debug logs
  • Set temperature limit to 95°C on iBTS before cooldown
  • Lower MTU for cellular communications down to 1420
  • Extend network-monitoring to handle new unstabilities experienced on the field

Restrictions

  • IPSec is not yet supported
  • Some issues with the Wi-Fi interface (instabilities, no fallback…) on Wirnet iFemtoCell
  • When upgrading from KerOS firmware 4.x, all trustzone secrets are lost
  • When upgrading from KerOS FW 4.3.3, a hardware reset is necessary for FW 5.x burner to correctly detect USB
  • Update status for an update from KerOS FW 5.1.x, FW 5.2.x or FW 5.3.x is in error, but the update is working fine
  • No more support of GSM dongles (please contact Kerlink if you plan to use one)
  • When iZepto-E is powered by a computer, it cannot benefit from the connection of a gateway in router mode
  • The activation/deactivation of the GSM from the local web interface takes some time to execute, so previous activation status remains displayed for a while. A page refresh after a delay of 15-20s after the action shows the right status
  • TAI clock offset can not be set on iStation with NEO-M9N. Class B does not work.

Firmware

Compatibility

  • Compatible with Wirnet™ i-series gateways (Wirnet iBTS, Wirnet iFemtoCell, Wirnet iStation, Wirnet iFemtoCell-evolution, Wirnet iZeptoCell Ethernet, Wirnet iZeptoCell Cellular).

Software

  • Compatible with Wirnet™ i-series gateways secured with Kerlink Production fuses or without any fuses flashed.
  • Regular update (keros.ipk) is incompatible with firmware older than v5.x

  • To upgrade the system from KerOS version 4.3.3 to KerOS version 5.x the use of a liveburner is MANDATORY. Two possibilities are available:
  • Upgrade with a custom liveburner. It allows to keep some elements like gateway configuration. To use a custom liveburner, please refer to the dedicated page: Major version upgrade with a custom liveburner.
  • Upgrade with a regular liveburner (erasing the whole partition to reinstall the firmware)

Delivery

The firmware is released in two formats: KerOS and Liveburner.

KerOS : Update the Firmware
To update the firmware from v5.x, the regular update procedure can be used. See system upgrade page.


Liveburner : Reset the Firmware of the product

  • Update stock version with FW 5.12.0.
  • Reset the default password on your gateway.
  • Erase the whole partition to reinstall the firmware.