Wirnet iBTS and Wirnet iFemtoCell can be configured using SMS command. Most feature available of the web interface and the REST API can be used via SMS.
All SMS command will follow the same syntax:
[login:password] [sms_command_id] sms_command sms_field sms_value
login: The login used for the board configuration. This value is always admin.password: The password is the same as the web interface password (pwd4admin by default)sms_command_id: ID defined by the customer to identify the SMS command. There is no default value. This ID is mandatory and must be 6 characters long.sms_command: The command to be executed with / separated fields.sms_field: The configuration field to be set/get (Optional).sms_value: The value that as to be set to a configuration field (Optional).All SMS reponses use the same syntax:
[sms_command_id:sms_command_status] sms_error_info
sms_command_id: The value of this field is equal to the value of the sms_command_id field used in the command. The purpose of this field is to match the command with the reponse.sms_command_status: ok or error. sms_error_info: SMS error information (Optional).| System command | Description | sms_command | sms_field | sms_value |
|---|---|---|---|---|
| Halt | Halt the board | system/halt | N/A | N/A |
| Reboot | Reboot the board | system/reboot | N/A | N/A |
| Update | Request a board update | system/update | N/A | N/A |
| Restore Backup | Request a backup restore | system/restore/backup | N/A | N/A |
| Restore Stock | Request a stock restore | system/restore/stock | N/A | N/A |
update, restore stock and restore backup SMS commands will only set up a flag used to record the request. reboot SMS command.
Examples:
Reboot command:
#SMS sent to the gateway [admin:pwd4admin] [reboot] system/reboot
#SMS response from the gateway [reboot:ok]
Restore stock command with wrong password:
#SMS sent to the gateway [admin:badpassword] [rstock] system/restore/stock
#SMS response from the gateway [rstock:error] login/password
There are two kinds of configuration commands: get_value commands and set_value commands.
| Command Description | sms_command | sms_field | sms_value |
|---|---|---|---|
| Get CPU usage | configuration/get_value | statm.cpu | N/A |
| Get RAM usage | configuration/get_value | statm.ram | N/A |
| Get userdisk usage | configuration/get_value | statm.userdisk | N/A |
| Get board temperature | configuration/get_value | statm.temperature | N/A |
| Get ethernet connectivity state | configuration/get_value | statm.lan.state | N/A |
| Get ethernet hardware address | configuration/get_value | statm.lan.hardware.address | N/A |
| Get ethernet IP address | configuration/get_value | statm.lan.address | N/A |
| Get ethernet broadcast IP address | configuration/get_value | statm.lan.broadcast | N/A |
| Get ethernet netmask | configuration/get_value | statm.lan.netmask | N/A |
| Get GSM connectivity state | configuration/get_value | statm.gsm.state | N/A |
| Get GSM IP address | configuration/get_value | statm.gsm.address | N/A |
| Get GSM netmask | configuration/get_value | statm.gsm.netmask | N/A |
| Get CPU board serial number | configuration/get_value | statm.serialnumber | N/A |
| Get Keros firmware version | configuration/get_value | statm.version | N/A |
Get board platform type (ibts or ifemto) | configuration/get_value | statm.platform | N/A |
| Get ethernet connectivity state | configuration/get_value | sysma.lan.enable | N/A |
Get ethernet connectivity mode: off,dhcp or static address_ip netmask gateway_ip dns_ip1,dns_ip2 (dns optionnal) | configuration/get_value | sysma.lan.ipv4 | N/A |
| Get ethernet IP address (only for static connectivity mode) | configuration/get_value | sysma.lan.ipv4_address | N/A |
| Get ethernet netmask (only for static connectivity mode) | configuration/get_value | sysma.lan.ipv4_netmask | N/A |
| Get ethernet gateway IP (only for static connectivity mode) | configuration/get_value | sysma.lan.ipv4_gateway | N/A |
| Get list of ethernet DNS IP (only for static connectivity mode) | configuration/get_value | sysma.lan.ipv4_dns | N/A |
Get GSM connectivity state (true or false) | configuration/get_value | sysma.gsm.enable | N/A |
| Get GSM operator list (MNC,MCC,APN,login,user) | configuration/get_value | sysma.gsm.operators | N/A |
| Get time synchronization mode (auto or manual) | configuration/get_value | timem.mode | N/A |
| Get list of NTP address | configuration/get_value | timem.ntp | N/A |
| Get timezone use on the board | configuration/get_value | timem.timezone | N/A |
| Get current date (yyyymmddHHMMSS) | configuration/get_value | timem.date | N/A |
Example:
Get GSM IP address:
#SMS sent to the gateway [admin:pwd4admin] [getgsm] configuration/get_value statm.gsm.address
#SMS response from the gateway [getgsm:ok] "10.172.108.48"
| Command Description | sms_command | sms_field | sms_value |
|---|---|---|---|
| Set admin user password | configuration/set_value | sysma.password | New password. ex:“mynewpassword” |
| Set ethernet connectivity state | configuration/set_value | sysma.lan.enable | true or false |
| Set ethernet connectivity mode | configuration/set_value | sysma.lan.ipv4 | “off”,“dhcp” or “static address_ip netmask gateway_ip dns_ip1,dns_ip2” (dns optionnal) |
| Set ethernet IP address | configuration/set_value | sysma.lan.ipv4_address | IP address. ex:“192.168.4.10” |
| Set ethernet netmask | configuration/set_value | sysma.lan.ipv4_netmask | Mask value. ex:“255.255.254.0” |
| Set ethernet gateway IP | configuration/set_value | sysma.lan.ipv4_gateway | IP address. ex:“192.168.4.1” |
| Set list of ethernet DNS IP | configuration/set_value | sysma.lan.ipv4_dns | IP addresses. ex:“192.168.1.1,192.168.1.2” |
| Set GSM connectivity state | configuration/set_value | sysma.gsm.enable | true or false |
| Add a GSM operator | configuration/set_value | sysma.gsm.add_operator | MNC,MCC,APN,login,user. ex:“124,10,myapn,user,pass” or “123,10,,,” |
| Remove a GSM operator | configuration/set_value | sysma.gsm.remove_operator | MNC,MCC. ex:“124,10” |
| Update a GSM operator | configuration/set_value | sysma.gsm.update_operator | MNC,MCC,APN,login,user. ex:“124,10,myapn2,,” |
| Time synchronization mode | configuration/set_value | timem.mode | “auto” or “manual” |
| Set List of NTP address | configuration/set_value | timem.ntp | List of NTP address. ex:“0.pool.ntp.org,1.pool.ntp.org” |
| Set Timezone use on the board | configuration/set_value | timem.timezone | Timezone. ex:“Europe/Paris” |
| Set a date (yyyymmddHHMMSS) | configuration/set_value | timem.date | Date. ex:“20180710192000” |
Examples:
Set admin user password:
#SMS sent to the gateway [admin:pwd4admin] [newpwd] configuration/set_value sysma.password "mynewpassword"
#SMS response from the gateway [newpwd:ok]
Wirnet iBTS and Wirnet iFemtoCell are able to send and receive SMS if the mobile network is properly configured. Modems are identified by manufacturer_X where X is a number. This can vary for the Wirnet iBTS if it is a dual-SIM device (always 0 for Wirnet iFemtoCell). The manufacturer is always sierra for Wirnet iBTS.
To retrieve the identifier, use the gsmdiag.py command.
Here is an output of /tmp/gsmdiag.txt. Two modems are displayed, and only one has a SIM card present. Its identifier is /sierra_0.
root@klk-lpbs-060434:~ # gsmdiag.py Diagnostic written in /tmp/gsmdiag.txt root@klk-lpbs-060434:~ # cat /tmp/gsmdiag.txt Number of modems: 2 [Modem:/sierra_1] Syspath:/sys/devices/soc0/soc/2100000.aips-bus/2184200.usb/ci_hdrc.1/usb2/2-1/2-1.3 HardwarePosition:1,1 Powered:1 Online:0 Manufacturer:Sierra Wireless, Incorporated Model:MC7304 Revision:SWI9X15C_05.05.58.00 r27038 carmd-fwbuild1 2015/03/04 21:30:23 [SimProps] Present:0 Error: no SIM in modem [Modem:/sierra_0] Powered:1 Online:1 Manufacturer:Sierra Wireless, Incorporated Model:MC7354 Revision:SWI9X15C_05.05.58.00 r27038 carmd-fwbuild1 2015/03/04 21:30:23 [SimProps] Present:1 CardIdentifier:895XXXXXXXXXXXX1015 SubscriberIdentity:3XXXXXXXXXXXXX3 LockedPins:dbus.Array([], signature=dbus.Signature('s'), variant_level=1) PinRequired:none [NetworkRegistrationProps] Status:registered MobileCountryCode:XXX MobileNetworkCode:YY Name:ABCD Strength:80 [ConnectionContexts] [/sierra_0/context1] Name:Internet Active:1 Type:internet Protocol:ip AccessPointName:apname Username:uname Password:pass AuthenticationMethod:chap
To send an SMS using the modem /sierra_0 (Wirnet iBTS):
dbus-send --system --print-reply --dest=org.ofono /sierra_0 org.ofono.MessageManager.SendMessage string:"+33XXXXXXXXXX" string:"test sms"
To send an SMS using the modem /huawei_0 (Wirnet iFemtoCell):
dbus-send --system --print-reply --dest=org.ofono /huawei_0 org.ofono.MessageManager.SendMessage string:"+33XXXXXXXXXX" string:"test sms"
Receive an SMS using a python test script :
File - receive SMS python script
#!/usr/bin/python2 from gi.repository import GLib import dbus import dbus.mainloop.glib def chunkstring(string, length): return (string[0+i:length+i] for i in range(0, len(string), length)) def incoming_message(message, details, path, interface): message_txt = str(message.encode('utf-8')) print("Size of message: %d" % len(message_txt)) print("%s" % (message_txt)) for line in chunkstring(message_txt, 40): print("%s" % line) for key in details: val = details[key] print(" %s = %s" % (key, val)) print(" %s = %s" % ('path',path)) print(" %s = %s" % ('interface', interface)) if __name__ == '__main__': dbus.mainloop.glib.DBusGMainLoop(set_as_default=True) bus = dbus.SystemBus() bus.add_signal_receiver(incoming_message, bus_name="org.ofono", signal_name = "ImmediateMessage", path_keyword="path", interface_keyword="interface") bus.add_signal_receiver(incoming_message, bus_name="org.ofono", signal_name = "IncomingMessage", path_keyword="path", interface_keyword="interface") mainloop = GLib.MainLoop() mainloop.run()